Recommended Citation
ITRC Report January 1, 2011.
Abstract
Drip/micro irrigation systems are often referred to as “low pressure” systems because the required emitter pressures are relatively low (6-12 psi). However, the pump discharge pressures of systems on flat ground throughout California average 40 psi. This report examines readily attainable system losses by examining individual components of the drip/micro system.
Disciplines
Bioresource and Agricultural Engineering
Copyright
© 2011 ITRC
Number of Pages
8
Included in
URL: https://digitalcommons.calpoly.edu/bae_fac/166