Abstract

With funding from the US Bureau of Reclamation, California – Great Basin Region (Region 10), the Cal Poly Irrigation Training & Research Center (ITRC) conducted flow measurement accuracy testing on two 10-inch insertion (saddle-mount) McCrometer Mc Mag3000 magnetic flow meters. The meters were two of 360 new meters that were purchased by Westlands Water District. One of the meters is shown in Figure 1. Testing was performed at the ITRC Water Resources Facility (WRF) using the ITRC gravimetric (weigh) tank as the standard flow rate measurement for all tests. The ITRC gravimetric tank has a NIST1-traceable uncertainty of ±0.1 percent (refer to ITRC Paper No. P 2020-0012 for further information).