Author ORCID Identifier
https://orcid.org/0000-0002-3237-5929
Recommended Citation
Postprint version. Published in Earthquake Spectra, Volume 36, Issue 4, May 26, 2020, pages 1864-1885.
The definitive version is available at https://doi.org/10.1177/8755293020919420.
Abstract
When evaluating seismically induced second-order effects in buildings, engineers and researchers are most familiar with these concerns in the context of multistory buildings with rigid diaphragms. However, similar concerns are valid for short single-story concrete or masonry-walled buildings with larger flexible diaphragms, which is a significant portion of the building stock in the United States. These rigid wall-flexible diaphragm (RWFD) buildings may have significant diaphragm drifts causing induced second-order effects. The stability coefficient currently found in ASCE 7 has traditionally been used by practitioners to evaluate the relative risk of P-delta instability in multistory buildings, but this indicator can be adapted for use in RWFD buildings. Using numerical studies following the Federal Emergency Management Agency (FEMA) P-695 collapse assessment methodology to evaluate the risk of collapse for a set of RWFD archetype buildings, a modified stability coefficient for RWFD buildings is found to capture the trend toward P-delta collapse and can act as a reasonable indicator without the need for heavy computational efforts.
Disciplines
Architectural Engineering
Copyright
© 2020 The Authors
Number of Pages
22
URL: https://digitalcommons.calpoly.edu/aen_fac/182