Abstract

With funding from the US Bureau of Reclamation, California – Great Basin Region (Region 10), the Cal Poly Irrigation Training & Research Center (ITRC) conducted flow measurement accuracy testing on two 10-inch insertion (strap-on saddle) McCrometer Water Specialties propeller flow meters. Both meters were new and recently purchased by Westlands Water District. One of the meters is shown in Figure 1. Testing was performed at the ITRC Water Resources Facility (WRF) using the ITRC volumetric tank as the standard flow rate measurement for all tests. The ITRC volumetric tank was calibrated with the NIST1-traceable ITRC gravimetric tank using a linear regression analysis.

Disciplines

Bioresource and Agricultural Engineering

Number of Pages

22

COinS
 

URL: https://digitalcommons.calpoly.edu/bae_fac/118